Ein lachendes weibliches Kind in Händen eines lachenden erwachsenen Mannes.
Ein lachendes weibliches Kind in Händen eines lachenden erwachsenen Mannes.
Breadcrumb-Navigation

Heat pumps

Heat pumps

Heat pumps are popular because they run on renewable energy, are environmentally friendly and cost-effective. With innovative heat pumps from NIBE you can reduce heating costs and make a valuable contribution to climate protection.

Our pro­duct ran­ge

  • Air-to-wa­ter heat pump Adapt Max

    The NIBE S2125 is an intelligent, inverter-controlled air/water heat pump. In combination with the indoor units, it automatically regulates the…

    Application
    Multi-family house, commercial, public buildings, new construction, renovation
    Installation
    Outdoor installation
    Operating range
    10 - 140 kW
  • Air-to-wa­ter heat pump NIBE S2125

    The NIBE S2125 is an intelligent, inverter-controlled air/water heat pump. In combination with the indoor units, it automatically regulates the…

    Application
    Single family house, new construction, renovation
    Installation
    Aussenaufstellung
    Operating range
    2 - 9 kW
  • Bri­ne/wa­ter heat pump NIBE S1155/S1156

    The NIBE S1155 is an intelligent, variable-capacity ground source heat pump for heating and domestic hot water production.

    Application
    Single-family house, multi-family house, new construction, renovation
    Installation
    Indoor installation
    Operating range
    1.5 - 25 kW
  • Air-to-wa­ter heat pump NIBE S2125

    The NIBE S2125 is an intelligent, inverter-controlled air/water heat pump. In combination with the indoor units, it automatically regulates the…

    Application
    Single family house, new construction, renovation
    Installation
    Outdoor installation
    Operating range
    2 - 9 kW
  • Air-to-wa­ter heat pump SWA

    The SWA air/water heat pump from Schmid offers proven technology with an excellent price-performance ratio. It is the ideal solution…

    Application
    Single-family house, multi-family house, new construction, renovation
    Installation
    Outdoor installation
    Operating range
    2 - 14 kW / Cascadable
  • Hot water heat pump ecodesign 300 WT/E

    Application
    Single-family house, renovation (replacement for electric water heater)
    Installation
    Indoor installation
    Operating range
    3,61 kW
  • Air-to-wa­ter heat pump NIBE F2120

    The NIBE F2120 is the air/water heat pump for maximum efficiency in new builds, modernization projects, or when replacing your…

    Application
    Single-family house, multi-family house, new construction, renovation
    Installation
    Outdoor installation
    Operating range
    2.2 - 15.4 kW / Cascadable up to 8 units (max. 108 kW at A-7/W35)
  • Air/water heat pump NIBE LA

    The NIBE LA 30 air/water heat pump, installed outdoors, is perfect for environmentally sound and energy-efficient heating. The LA 30…

    Application
    Single family house, new construction, renovation
    Installation
    Outdoor installation
    Operating range
    1.9 - 24.3 kW
  • Air-to-wa­ter heat pump NIBE LIV / LICV

    The inverter technology of the NIBE LIV/LICV adapts perfectly to the requirements of the house and its occupants, ensuring the…

    Application
    Single-family house and especially for new construction (but also for renovation).
    Installation
    Indoor installation
    Operating range
    2.6 - 10.3 kW
  • Air-to-wa­ter heat pump NIBE LI

    The NIBE LI series is ideal for environmentally sound, energy-efficient, and convenient heating. It fits in any basement and is…

    Application
    Single-family house, multi-family house, especially for renovation (but also new construction)
    Installation
    Indoor installation
    Operating range
    9.00 - 24.3 kW
  • Brine/Water-heat pump NIBE S1255-S1256

    The NIBE S1255 is an intelligent, variable-capacity ground source heat pump with an integrated domestic hot water tank (180 L).

    Application
    Single-family house, multi-family house, new construction, renovation
    Installation
    Indoor installation
    Operating range
    1.5 - 16 kW
  • Bri­ne/wa­ter heat pump NIBE F1345

    The NIBE F1345 is a powerful heat pump for larger single-family homes, multi-family homes, or commercial and industrial buildings.

    Application
    Multi-family houses, commercial and industrial, public buildings, new construction, renovation
    Installation
    Indoor installation
    Operating range
    24 - 60 kW
  • Bri­ne/wa­ter heat pump NIBE F1355

    The NIBE F1355 with two integrated cooling modules is ideal for heating apartment buildings, industrial buildings, and public buildings.

    Application
    Multi-family houses, commercial and industrial, public buildings, new construction, renovation
    Installation
    Indoor installation
    Operating range
    4 - 28 kW and 6 - 43 kW
  • Hot water heat pump ecodesign 400 WT

    Application
    Single-family house, renovation (replacement for electric water heater)
    Installation
    Indoor installation
    Operating range
    3,15 kW
  • Brauchwasser-Wärmepumpe KNV B 270

    Application
    Einfamilienhaus, Sanierung (Ersatz für Elektrowassererwärmer)
    Installation
    Innenaufstellung
    Operating range
    2.92 kW
  • Air-to-wa­ter heat pump NIBE S2125

    The NIBE S2125 is an intelligent, inverter-controlled air/water heat pump. In combination with the indoor units, it automatically regulates the…

    Application
    Single family house, new construction, renovation
    Installation
    Aussenaufstellung
    Operating range
    2 - 9 kW
  • Bri­ne/wa­ter heat pump NIBE F1355

    The NIBE F1355 with two integrated cooling modules is ideal for heating apartment buildings, industrial buildings, and public buildings.

    Application
    Multi-family houses, commercial and industrial, public buildings, new construction, renovation
    Installation
    Indoor installation
    Operating range
    4 - 28 kW and 6 - 43 kW

Cli­ma­te pre­mi­um

Are you replacing a fossil gas or oil heating system with a renewable heating system? Benefit from attractive subsidies.

Fre­quent­ly as­ked ques­ti­ons?

The heat pump extracts thermal energy from the ambient air. The refrigerant absorbs this heat in the heat exchanger (evaporator) and is then compressed in the compressor. The heat generated in this process is used for heating and hot water production via another heat exchanger. In summer, the cycle can also be used for cooling by reversing the process.

The heat pump extracts thermal energy from the ground using a geothermal probe or groundwater. The refrigerant absorbs this heat in the heat exchanger (evaporator) and is then compressed in the compressor. The heat generated in this process is used for heating and hot water production via another heat exchanger. In summer, the cycle can also be used for cooling by reversing the process.

Heat pumps are suitable for both and can therefore be used in new buildings and old buildings undergoing renovation. With the latest generation of heat pumps, flow temperatures of up to 70° can be achieved.
However, it may be worth replacing or adding new radiators with a larger heating surface area in order to increase the efficiency of the heat pump. Seek advice from a specialist. In general, energy-saving measures should be considered for the building envelope in order to directly reduce the heat demand and thus reduce the flow temperatures and increase the efficiency of the heat pump.

Yes, because all our heat pump systems are designed for the design temperature. However, there are some differences between the various heat pump systems that need to be taken into account:

Air/water heat pumps:
Air/water heat pumps have a lower operating limit (approx. -25°C). For heating systems, this means that the heat output is guaranteed up to the design temperature (in the Swiss Plateau, for example, at -7°C). If the outside temperature falls below this design temperature, the auxiliary heating can switch on automatically. Statistically speaking, however, this is extremely rare.

Brine/water heat pumps:
With brine/water heat pumps, it is important to dimension the geothermal probes correctly. The geothermal energy at depth is constant and changes only minimally, even if the top layer of soil is frozen.

A heat pump with a COP of 5 requires 1/5 of the total energy produced in the form of electrical energy, while 4/5 of the energy is obtained from the environment (ambient air, geothermal probe, etc.).
The COP is highly dependent on the source temperature and the flow temperature. The higher the source temperature and the lower the flow temperature, the higher the COP and the energy efficiency.
In combination with a PV system, the amount of electricity consumed can be increased and energy costs reduced.

The sound insulation of heat pumps can be improved through structural measures. The most important measure is to physically decouple the heat pump from the house. Pipes must also be physically decoupled using suitable mounting systems. Sound insulation hoods or sound insulation walls can also significantly reduce noise levels.

Heat pumps are generally very low-maintenance. However, a heat pump should not be neglected. Contamination on the outdoor unit or in the heating circuit, incorrect settings, incorrect heating curves, etc. can damage the heat pump or reduce its efficiency. Periodic maintenance is therefore always beneficial and extends the service life.

Do you have any ques­ti­ons?

Benefit from our many years of experience and let our specialists advise you individually, without obligation and free of charge.

This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.